Energy Performance Certificate

33 Porchester Close, SE5 8EW

EPC Report

Energy rating

Current: 49 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 42 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 80 Potential: 80
Field Value
LMK KEY 0010-2131-0070-2422-1435
ADDRESS1 33 Porchester Close
ADDRESS2
ADDRESS3
POSTCODE SE5 8EW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-03-29
LOCAL AUTHORITY E09000022
CONSTITUENCY E14001205
COUNTY
LODGEMENT DATE 2022-05-14
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 348
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 141
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 558
HEATING COST POTENTIAL 410
HOT WATER COST CURRENT 433
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33 Porchester Close
LOCAL AUTHORITY LABEL Lambeth
CONSTITUENCY LABEL Dulwich and West Norwood
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2022-05-14 15:26:47
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10000443101
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew