Energy Performance Certificate

36 BRENT TERRACE, NW2 1BX

EPC Report

Energy rating

Current: 73 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 61 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 75 Potential: 75
Field Value
LMK KEY 0010-2102-4250-2029-7035
ADDRESS1 36 BRENT TERRACE
ADDRESS2
ADDRESS3
POSTCODE NW2 1BX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-05-22
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001238
COUNTY
LODGEMENT DATE 2021-05-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 188
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 639
HEATING COST POTENTIAL 504
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 53
TOTAL FLOOR AREA 79
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 95
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 95% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36 BRENT TERRACE
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Finchley and Golders Green
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-05-24 14:43:32
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 200014190
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew