Energy Performance Certificate
106 RAEMOIR AVENUE , BANCHORY, AB31 5UF
Energy rating
Current: 56 D | Potential: 85 B
Environmental impact (CO₂)
Current: 57
| Potential: 88
| Field | Value |
|---|---|
| Id | 2957385 |
| BUILDING REFERENCE NUMBER | 1000921547 |
| OSG REFERENCE NUMBER | 151038888 |
| ADDRESS1 | 106 RAEMOIR AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | BANCHORY |
| POSTCODE | AB31 5UF |
| INSPECTION DATE | 2016-04-18 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-08-26 |
| ENERGY CONSUMPTION CURRENT | 398.00 |
| TOTAL FLOOR AREA | 49 |
| 3 YR ENERGY COST CURRENT | 2613.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 921.0000 |
| CURRENT ENERGY EFFICIENCY | 56 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 57 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 88 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 69.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 68; Energy Rating after improvement: D 62; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 130; Energy Rating after improvement: C 69; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 78; Energy Rating after improvement: D 59; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 243; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 88; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 32; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.40 |
| CO2 EMISSIONS POTENTIAL | 2.20 |
| HEATING COST CURRENT | 1677.0000 |
| HEATING COST POTENTIAL | 1155.0000 |
| HOT WATER COST CURRENT | 831.00 |
| HOT WATER COST POTENTIAL | 432.00 |
| LIGHTING COST CURRENT | 105.00 |
| LIGHTING COST POTENTIAL | 105.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9353 |
| WATER HEATING DEMAND | 1793 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1646 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000317 (Banchory) |
| ENERGY CONSUMPTION POTENTIAL | 141.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMR |
| CONSTITUENCY LABEL | Banchory and Mid Deeside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01006860 (Banchory East - 02) |
| CREATED AT | 26/08/2016 16:01:33 |
| REPORT REFERENCE NUMBER | 9887-1009-4204-5616-2904 |
| Source file | Q3 2016.csv |
| Address display | 106 RAEMOIR AVENUE , BANCHORY |
| Nation | scotland |