Energy Performance Certificate

123 RAEMOIR AVENUE , BANCHORY, AB31 5UF

EPC Report

Energy rating

Current: 48 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 45 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 85 Potential: 85
Field Value
Id 2768125
BUILDING REFERENCE NUMBER 1000921564
OSG REFERENCE NUMBER 151038905
ADDRESS1 123 RAEMOIR AVENUE
ADDRESS2
ADDRESS3 BANCHORY
POSTCODE AB31 5UF
INSPECTION DATE 2022-04-14
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2022-04-26
ENERGY CONSUMPTION CURRENT 481.00
TOTAL FLOOR AREA 74
3 YR ENERGY COST CURRENT 5340.0000
3 YR ENERGY SAVINGS POTENTIAL 3192.0000
CURRENT ENERGY EFFICIENCY 48
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 84
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 45
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 85
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 81.00
IMPROVEMENTS Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 21; Energy Rating after improvement: D 55; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 38; Energy Rating after improvement: D 57; Environmental Rating after improvement: E 52; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 34; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 321; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 211; Energy Rating after improvement: D 55; Environmental Rating after improvement: E 50; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 758; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 72; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed) | Solid brick, as built, insulated (assumed)
WALL ENERGY EFF Poor | Very Good
WALL ENV EFF Poor | Very Good
ROOF DESCRIPTION Pitched, 300 mm loft insulation | Pitched, insulated (assumed)
ROOF ENERGY EFF Very Good | Good
ROOF ENV EFF Very Good | Good
FLOOR DESCRIPTION Solid, insulated (assumed) | Suspended, insulated
FLOOR ENERGY EFF N/A | N/A
FLOOR ENV EFF N/A | N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 6.00
CO2 EMISSIONS POTENTIAL 4.10
HEATING COST CURRENT 4128.0000
HEATING COST POTENTIAL 1734.0000
HOT WATER COST CURRENT 846.00
HOT WATER COST POTENTIAL 207.00
LIGHTING COST CURRENT 366.00
LIGHTING COST POTENTIAL 207.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 8564
WATER HEATING DEMAND 2402
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -1315
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.4
DATA ZONE S01000317 (Banchory)
ENERGY CONSUMPTION POTENTIAL 143.00
EXTENSION COUNT 1
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
LOW ENERGY LIGHTING 0.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Aberdeenshire
MAINS GAS FLAG
MAIN HEATING CATEGORY room heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2602
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE none of the above
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QBMR
CONSTITUENCY LABEL Banchory and Mid Deeside
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01006860 (Banchory East - 02)
CREATED AT 26/04/2022 16:45:01
REPORT REFERENCE NUMBER 9244-1009-6204-5712-2204
Source file Q2 2022.csv
Address display 123 RAEMOIR AVENUE , BANCHORY
Nation scotland