Energy Performance Certificate
60 SOUTH GYLE WYND , SOUTH GYLE , EDINBURGH, EH12 9HJ
Energy rating
Current: 66 D | Potential: 77 C
Environmental impact (CO₂)
Current: 64
| Potential: 80
| Field | Value |
|---|---|
| Id | 3586666 |
| BUILDING REFERENCE NUMBER | 1001139643 |
| OSG REFERENCE NUMBER | 906228569 |
| ADDRESS1 | 60 SOUTH GYLE WYND |
| ADDRESS2 | SOUTH GYLE |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2023-10-03 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-10-05 |
| ENERGY CONSUMPTION CURRENT | 312.00 |
| TOTAL FLOOR AREA | 46 |
| 3 YR ENERGY COST CURRENT | 4059.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1569.0000 |
| CURRENT ENERGY EFFICIENCY | 66 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 64 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 55.00 |
| IMPROVEMENTS | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 210; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 195; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 117; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 3147.0000 |
| HEATING COST POTENTIAL | 1650.0000 |
| HOT WATER COST CURRENT | 666.00 |
| HOT WATER COST POTENTIAL | 594.00 |
| LIGHTING COST CURRENT | 246.00 |
| LIGHTING COST POTENTIAL | 246.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6378 |
| WATER HEATING DEMAND | 1637 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1543 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.32 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 178.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 05/10/2023 10:33:58 |
| REPORT REFERENCE NUMBER | 9160-2397-4100-2307-0165 |
| Source file | Q4 2023.csv |
| Address display | 60 SOUTH GYLE WYND , SOUTH GYLE , EDINBURGH |
| Nation | scotland |