Energy Performance Certificate
115 RAEMOIR AVENUE , BANCHORY, AB31 5UF
Energy rating
Current: 36 F | Potential: 85 B
Environmental impact (CO₂)
Current: 37
| Potential: 83
| Field | Value |
|---|---|
| Id | 3513444 |
| BUILDING REFERENCE NUMBER | 1000921556 |
| OSG REFERENCE NUMBER | 151038897 |
| ADDRESS1 | 115 RAEMOIR AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | BANCHORY |
| POSTCODE | AB31 5UF |
| INSPECTION DATE | 2021-12-20 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-12-21 |
| ENERGY CONSUMPTION CURRENT | 548.00 |
| TOTAL FLOOR AREA | 87 |
| 3 YR ENERGY COST CURRENT | 7215.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 5133.0000 |
| CURRENT ENERGY EFFICIENCY | 36 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 37 |
| CURRENT ENVIRONMENTAL RATING | F |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 93.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 206; Energy Rating after improvement: E 48; Environmental Rating after improvement: E 46; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 17; Energy Rating after improvement: E 49; Environmental Rating after improvement: E 47; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 1136; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 33; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 317; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 83; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 277; Energy Rating after improvement: E 43; Environmental Rating after improvement: E 42; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 42; Energy Rating after improvement: E 50; Environmental Rating after improvement: E 48; Green Deal Eligible: N | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 8.10 |
| CO2 EMISSIONS POTENTIAL | 5.80 |
| HEATING COST CURRENT | 5946.0000 |
| HEATING COST POTENTIAL | 1632.0000 |
| HOT WATER COST CURRENT | 867.00 |
| HOT WATER COST POTENTIAL | 216.00 |
| LIGHTING COST CURRENT | 402.00 |
| LIGHTING COST POTENTIAL | 234.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 12651 |
| WATER HEATING DEMAND | 2177 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1766 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000317 (Banchory) |
| ENERGY CONSUMPTION POTENTIAL | 148.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2605 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMR |
| CONSTITUENCY LABEL | Banchory and Mid Deeside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01006860 (Banchory East - 02) |
| CREATED AT | 21/12/2021 08:43:21 |
| REPORT REFERENCE NUMBER | 9150-2610-5020-2229-6975 |
| Source file | Q4 2021.csv |
| Address display | 115 RAEMOIR AVENUE , BANCHORY |
| Nation | scotland |