Energy Performance Certificate
122 RAEMOIR AVENUE , BANCHORY, AB31 5UF
Energy rating
Current: 67 D | Potential: 84 B
Environmental impact (CO₂)
Current: 68
| Potential: 83
| Field | Value |
|---|---|
| Id | 2768238 |
| BUILDING REFERENCE NUMBER | 1000921563 |
| OSG REFERENCE NUMBER | 151038904 |
| ADDRESS1 | 122 RAEMOIR AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | BANCHORY |
| POSTCODE | AB31 5UF |
| INSPECTION DATE | 2021-12-15 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2022-04-26 |
| ENERGY CONSUMPTION CURRENT | 265.00 |
| TOTAL FLOOR AREA | 70 |
| 3 YR ENERGY COST CURRENT | 2451.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 339.0000 |
| CURRENT ENERGY EFFICIENCY | 67 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 84 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 68 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 46.00 |
| IMPROVEMENTS | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 38; Energy Rating after improvement: C 69; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 306; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 83; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £40; Typical Saving: 52; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 71; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 22; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 75 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, insulated |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.20 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 1839.0000 |
| HEATING COST POTENTIAL | 1749.0000 |
| HOT WATER COST CURRENT | 249.00 |
| HOT WATER COST POTENTIAL | 183.00 |
| LIGHTING COST CURRENT | 363.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 8270 |
| WATER HEATING DEMAND | 2045 |
| IMPACT LOFT INSULATION | -665 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000317 (Banchory) |
| ENERGY CONSUMPTION POTENTIAL | 158.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMR |
| CONSTITUENCY LABEL | Banchory and Mid Deeside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01006860 (Banchory East - 02) |
| CREATED AT | 26/04/2022 16:42:00 |
| REPORT REFERENCE NUMBER | 9150-2315-6020-2299-0935 |
| Source file | Q2 2022.csv |
| Address display | 122 RAEMOIR AVENUE , BANCHORY |
| Nation | scotland |