Energy Performance Certificate

127 RAEMOIR AVENUE , BANCHORY, AB31 5UF

EPC Report

Energy rating

Current: 69 C | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 65 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 84 Potential: 84
Field Value
Id 2398306
BUILDING REFERENCE NUMBER 1000921568
OSG REFERENCE NUMBER 151038909
ADDRESS1 127 RAEMOIR AVENUE
ADDRESS2
ADDRESS3 BANCHORY
POSTCODE AB31 5UF
INSPECTION DATE 2022-03-07
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2022-03-08
ENERGY CONSUMPTION CURRENT 252.00
TOTAL FLOOR AREA 98
3 YR ENERGY COST CURRENT 2664.0000
3 YR ENERGY SAVINGS POTENTIAL 636.0000
CURRENT ENERGY EFFICIENCY 69
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 86
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 65
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 84
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 44.00
IMPROVEMENTS Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 51; Energy Rating after improvement: C 71; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 78; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 39; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 306; Energy Rating after improvement: B 86; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 43; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 76; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed) | Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Poor | Good
WALL ENV EFF Poor | Good
ROOF DESCRIPTION Pitched, 250 mm loft insulation | Pitched, insulated (assumed)
ROOF ENERGY EFF Good | Average
ROOF ENV EFF Good | Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.40
CO2 EMISSIONS POTENTIAL 2.20
HEATING COST CURRENT 2064.0000
HEATING COST POTENTIAL 1560.0000
HOT WATER COST CURRENT 366.00
HOT WATER COST POTENTIAL 234.00
LIGHTING COST CURRENT 234.00
LIGHTING COST POTENTIAL 234.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 13996
WATER HEATING DEMAND 2908
IMPACT LOFT INSULATION -336
IMPACT CAVITY WALL INSULATION -1284
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.28
DATA ZONE S01000317 (Banchory)
ENERGY CONSUMPTION POTENTIAL 128.00
EXTENSION COUNT 2
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 13
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 5
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 5
LOCAL AUTHORITY LABEL Aberdeenshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QBMR
CONSTITUENCY LABEL Banchory and Mid Deeside
WIND TURBINE COUNT 0
BUILT FORM End-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01006860 (Banchory East - 02)
CREATED AT 08/03/2022 09:23:30
REPORT REFERENCE NUMBER 8900-4235-0122-0006-1723
Source file Q1 2022.csv
Address display 127 RAEMOIR AVENUE , BANCHORY
Nation scotland