Energy Performance Certificate
PF1 , 7 SOUTH OXFORD STREET , EDINBURGH, EH8 9QF
Energy rating
Current: 69 C | Potential: 78 C
Environmental impact (CO₂)
Current: 67
| Potential: 79
| Field | Value |
|---|---|
| Id | 2435625 |
| BUILDING REFERENCE NUMBER | 1000512705 |
| OSG REFERENCE NUMBER | 906363333 |
| ADDRESS1 | PF1 |
| ADDRESS2 | 7 SOUTH OXFORD STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH8 9QF |
| INSPECTION DATE | 2023-02-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-02-03 |
| ENERGY CONSUMPTION CURRENT | 242.00 |
| TOTAL FLOOR AREA | 71 |
| 3 YR ENERGY COST CURRENT | 2265.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 672.0000 |
| CURRENT ENERGY EFFICIENCY | 69 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 67 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 43.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 83; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 141; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.00 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 1722.0000 |
| HEATING COST POTENTIAL | 1047.0000 |
| HOT WATER COST CURRENT | 321.00 |
| HOT WATER COST POTENTIAL | 324.00 |
| LIGHTING COST CURRENT | 222.00 |
| LIGHTING COST POTENTIAL | 222.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 8685 |
| WATER HEATING DEMAND | 2014 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2793 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3 |
| DATA ZONE | S01002028 (Dalkeith Rd) |
| ENERGY CONSUMPTION POTENTIAL | 152.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 14.8 |
| CONSTITUENCY | 00QPMQ |
| CONSTITUENCY LABEL | Southside/Newington |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Enclosed End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008601 (Newington and Dalkeith Road - 03) |
| CREATED AT | 03/02/2023 08:57:35 |
| REPORT REFERENCE NUMBER | 5717-0122-7000-0212-5202 |
| Source file | Q1 2023.csv |
| Address display | PF1 , 7 SOUTH OXFORD STREET , EDINBURGH |
| Nation | scotland |