Energy Performance Certificate
79 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL, ML4 3EX
Energy rating
Current: 71 C | Potential: 89 B
Environmental impact (CO₂)
Current: 71
| Potential: 90
| Field | Value |
|---|---|
| Id | 2920123 |
| BUILDING REFERENCE NUMBER | 1001432533 |
| OSG REFERENCE NUMBER | 118117316 |
| ADDRESS1 | 79 ROCKBURN CRESCENT |
| ADDRESS2 | HATTONRIGG |
| ADDRESS3 | BELLSHILL |
| POSTCODE | ML4 3EX |
| INSPECTION DATE | 2025-05-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-05-08 |
| ENERGY CONSUMPTION CURRENT | 248.00 |
| TOTAL FLOOR AREA | 50 |
| 3 YR ENERGY COST CURRENT | 2220.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 396.0000 |
| CURRENT ENERGY EFFICIENCY | 71 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 89 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 71 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 90 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 44.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 393; Energy Rating after improvement: B 89; Environmental Rating after improvement: B 90; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 47; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 50; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 35; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 1.40 |
| HEATING COST CURRENT | 1659.0000 |
| HEATING COST POTENTIAL | 1368.0000 |
| HOT WATER COST CURRENT | 351.00 |
| HOT WATER COST POTENTIAL | 246.00 |
| LIGHTING COST CURRENT | 210.00 |
| LIGHTING COST POTENTIAL | 210.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6276 |
| WATER HEATING DEMAND | 1819 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -737 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.43 |
| DATA ZONE | S01004685 (Hattonrigg) |
| ENERGY CONSUMPTION POTENTIAL | 90.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 75.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | North Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QZMP |
| CONSTITUENCY LABEL | Bellshill |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01011528 (Bellshill Central - 01) |
| CREATED AT | 08/05/2025 11:20:45 |
| REPORT REFERENCE NUMBER | 3615-3325-5100-0218-4202 |
| Source file | Q2 2025.csv |
| Address display | 79 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL |
| Nation | scotland |