Energy Performance Certificate
3F2 , 1 SOUTH OXFORD STREET , EDINBURGH, EH8 9QF
Energy rating
Current: 56 D | Potential: 63 D
Environmental impact (CO₂)
Current: 48
| Potential: 56
| Field | Value |
|---|---|
| Id | 3476420 |
| BUILDING REFERENCE NUMBER | 1000512655 |
| OSG REFERENCE NUMBER | 906363284 |
| ADDRESS1 | 3F2 |
| ADDRESS2 | 1 SOUTH OXFORD STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH8 9QF |
| INSPECTION DATE | 2020-10-23 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-11-05 |
| ENERGY CONSUMPTION CURRENT | 336.00 |
| TOTAL FLOOR AREA | 107 |
| 3 YR ENERGY COST CURRENT | 3975.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 681.0000 |
| CURRENT ENERGY EFFICIENCY | 56 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 63 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 48 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 56 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 59.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 30; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 53; Green Deal Eligible: N | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 69; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 128; Energy Rating after improvement: D 60; Environmental Rating after improvement: E 52; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Partial double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 60% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.30 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 3117.0000 |
| HEATING COST POTENTIAL | 2652.0000 |
| HOT WATER COST CURRENT | 501.00 |
| HOT WATER COST POTENTIAL | 387.00 |
| LIGHTING COST CURRENT | 357.00 |
| LIGHTING COST POTENTIAL | 255.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 19696 |
| WATER HEATING DEMAND | 3426 |
| IMPACT LOFT INSULATION | -10189 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -3519 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.2 |
| DATA ZONE | S01002028 (Dalkeith Rd) |
| ENERGY CONSUMPTION POTENTIAL | 275.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 60.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 70 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 4.02 |
| CONSTITUENCY | 00QPMQ |
| CONSTITUENCY LABEL | Southside/Newington |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008601 (Newington and Dalkeith Road - 03) |
| CREATED AT | 05/11/2020 10:48:49 |
| REPORT REFERENCE NUMBER | 2875-1905-5200-6820-1200 |
| Source file | Q4 2020.csv |
| Address display | 3F2 , 1 SOUTH OXFORD STREET , EDINBURGH |
| Nation | scotland |