Energy Performance Certificate

2F2 , 5 SOUTH OXFORD STREET , EDINBURGH, EH8 9QF

EPC Report

Energy rating

Current: 69 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 67 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 85 Potential: 85
Field Value
Id 2192397
BUILDING REFERENCE NUMBER 1000512680
OSG REFERENCE NUMBER 906363308
ADDRESS1 2F2
ADDRESS2 5 SOUTH OXFORD STREET
ADDRESS3 EDINBURGH
POSTCODE EH8 9QF
INSPECTION DATE 2016-02-29
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-03-02
ENERGY CONSUMPTION CURRENT 241.00
TOTAL FLOOR AREA 69
3 YR ENERGY COST CURRENT 2166.0000
3 YR ENERGY SAVINGS POTENTIAL 993.0000
CURRENT ENERGY EFFICIENCY 69
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 82
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 67
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 85
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 42.00
IMPROVEMENTS Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 170; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 65; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £35; Typical Saving: 40; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: N | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 57; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 81; Green Deal Eligible: Y |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Poor
WALL ENV EFF Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.90
CO2 EMISSIONS POTENTIAL 1.50
HEATING COST CURRENT 1536.0000
HEATING COST POTENTIAL 717.0000
HOT WATER COST CURRENT 342.00
HOT WATER COST POTENTIAL 309.00
LIGHTING COST CURRENT 288.00
LIGHTING COST POTENTIAL 147.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 6682
WATER HEATING DEMAND 1989
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -2963
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 3.06
DATA ZONE S01002028 (Dalkeith Rd)
ENERGY CONSUMPTION POTENTIAL 112.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
LOW ENERGY LIGHTING 0.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 7.2
CONSTITUENCY 00QPMQ
CONSTITUENCY LABEL Southside/Newington
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008601 (Newington and Dalkeith Road - 03)
CREATED AT 02/03/2016 12:55:23
REPORT REFERENCE NUMBER 2710-1005-8202-6826-1904
Source file Q1 2016.csv
Address display 2F2 , 5 SOUTH OXFORD STREET , EDINBURGH
Nation scotland