Energy Performance Certificate
110 SOUTH GYLE WYND , EDINBURGH, EH12 9HJ
Energy rating
Current: 48 E | Potential: 71 C
Environmental impact (CO₂)
Current: 45
| Potential: 74
| Field | Value |
|---|---|
| Id | 3057013 |
| BUILDING REFERENCE NUMBER | 1001139614 |
| OSG REFERENCE NUMBER | 906228389 |
| ADDRESS1 | 110 SOUTH GYLE WYND |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2019-09-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2019-09-27 |
| ENERGY CONSUMPTION CURRENT | 501.00 |
| TOTAL FLOOR AREA | 46 |
| 3 YR ENERGY COST CURRENT | 2739.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1269.0000 |
| CURRENT ENERGY EFFICIENCY | 48 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 45 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 74 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 88.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 181; Energy Rating after improvement: D 60; Environmental Rating after improvement: D 58; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 14; Energy Rating after improvement: D 61; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 55; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 118; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 16; Energy Rating after improvement: D 61; Environmental Rating after improvement: D 59; Green Deal Eligible: N | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 40; Energy Rating after improvement: E 50; Environmental Rating after improvement: E 47; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | To unheated space, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.00 |
| CO2 EMISSIONS POTENTIAL | 2.20 |
| HEATING COST CURRENT | 1899.0000 |
| HEATING COST POTENTIAL | 1065.0000 |
| HOT WATER COST CURRENT | 660.00 |
| HOT WATER COST POTENTIAL | 285.00 |
| LIGHTING COST CURRENT | 180.00 |
| LIGHTING COST POTENTIAL | 120.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6939 |
| WATER HEATING DEMAND | 3131 |
| IMPACT LOFT INSULATION | -534 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | 2.43 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 231.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| LOW ENERGY LIGHTING | 50.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2104 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 27/09/2019 15:29:32 |
| REPORT REFERENCE NUMBER | 2134-1011-1201-6891-3904 |
| Source file | Q3 2019.csv |
| Address display | 110 SOUTH GYLE WYND , EDINBURGH |
| Nation | scotland |