Energy Performance Certificate
126 SOUTH GYLE WYND , EDINBURGH, EH12 9HJ
Energy rating
Current: 70 C | Potential: 89 B
Environmental impact (CO₂)
Current: 67
| Potential: 87
| Field | Value |
|---|---|
| Id | 3056757 |
| BUILDING REFERENCE NUMBER | 1001139622 |
| OSG REFERENCE NUMBER | 906228407 |
| ADDRESS1 | 126 SOUTH GYLE WYND |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2019-06-25 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2019-07-05 |
| ENERGY CONSUMPTION CURRENT | 237.00 |
| TOTAL FLOOR AREA | 58 |
| 3 YR ENERGY COST CURRENT | 1716.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 330.0000 |
| CURRENT ENERGY EFFICIENCY | 70 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 89 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 67 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 87 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 46.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 28; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 43; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 39; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 296; Energy Rating after improvement: B 89; Environmental Rating after improvement: B 87; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, coal |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.60 |
| CO2 EMISSIONS POTENTIAL | 1.50 |
| HEATING COST CURRENT | 1215.0000 |
| HEATING COST POTENTIAL | 1029.0000 |
| HOT WATER COST CURRENT | 363.00 |
| HOT WATER COST POTENTIAL | 219.00 |
| LIGHTING COST CURRENT | 138.00 |
| LIGHTING COST POTENTIAL | 138.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6218 |
| WATER HEATING DEMAND | 2592 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -839 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 87.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 05/07/2019 11:33:02 |
| REPORT REFERENCE NUMBER | 2100-8356-0929-1122-1613 |
| Source file | Q3 2019.csv |
| Address display | 126 SOUTH GYLE WYND , EDINBURGH |
| Nation | scotland |