Energy Performance Certificate
124 SOUTH GYLE WYND , EDINBURGH, EH12 9HJ
Energy rating
Current: 72 C | Potential: 87 B
Environmental impact (CO₂)
Current: 72
| Potential: 86
| Field | Value |
|---|---|
| Id | 2959614 |
| BUILDING REFERENCE NUMBER | 1001139621 |
| OSG REFERENCE NUMBER | 906228405 |
| ADDRESS1 | 124 SOUTH GYLE WYND |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2016-09-15 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-09-16 |
| ENERGY CONSUMPTION CURRENT | 207.00 |
| TOTAL FLOOR AREA | 69 |
| 3 YR ENERGY COST CURRENT | 1857.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 216.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 87 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 72 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 86 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 36.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 260; Energy Rating after improvement: B 87; Environmental Rating after improvement: B 86; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 28; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 13; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 74; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 31; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, insulated (assumed) | Roof room(s), insulated (assumed) |
| ROOF ENERGY EFF | Average | Very Good |
| ROOF ENV EFF | Average | Very Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 67% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 1395.0000 |
| HEATING COST POTENTIAL | 1320.0000 |
| HOT WATER COST CURRENT | 273.00 |
| HOT WATER COST POTENTIAL | 180.00 |
| LIGHTING COST CURRENT | 189.00 |
| LIGHTING COST POTENTIAL | 141.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6785 |
| WATER HEATING DEMAND | 1871 |
| IMPACT LOFT INSULATION | -197 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | 2.35 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 103.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 67.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 16/09/2016 17:55:42 |
| REPORT REFERENCE NUMBER | 1216-2321-6100-0905-1992 |
| Source file | Q3 2016.csv |
| Address display | 124 SOUTH GYLE WYND , EDINBURGH |
| Nation | scotland |