Energy Performance Certificate

6 STANLEY GARDENS , MADDISTON , FALKIRK, FK2 0LN

EPC Report

Energy rating

Current: 66 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 66 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 86 Potential: 86
Field Value
Id 2994567
BUILDING REFERENCE NUMBER 1001393010
OSG REFERENCE NUMBER 136046856
ADDRESS1 6 STANLEY GARDENS
ADDRESS2 MADDISTON
ADDRESS3 FALKIRK
POSTCODE FK2 0LN
INSPECTION DATE 2017-08-30
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2017-08-30
ENERGY CONSUMPTION CURRENT 273.00
TOTAL FLOOR AREA 61
3 YR ENERGY COST CURRENT 2178.0000
3 YR ENERGY SAVINGS POTENTIAL 453.0000
CURRENT ENERGY EFFICIENCY 66
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 85
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 66
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 86
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 48.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 30; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 26; Energy Rating after improvement: C 69; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 58; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £45; Typical Saving: 37; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 67; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 255; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 86; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.90
CO2 EMISSIONS POTENTIAL 1.50
HEATING COST CURRENT 1578.0000
HEATING COST POTENTIAL 1401.0000
HOT WATER COST CURRENT 318.00
HOT WATER COST POTENTIAL 183.00
LIGHTING COST CURRENT 282.00
LIGHTING COST POTENTIAL 141.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 6062
WATER HEATING DEMAND 1877
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1999-2002
FLOOR HEIGHT 2.4
DATA ZONE S01002384 (Maddiston and Rumford)
ENERGY CONSUMPTION POTENTIAL 125.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
LOW ENERGY LIGHTING 0.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Falkirk
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QQMJ
CONSTITUENCY LABEL Upper Braes
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01009201 (Maddiston and Rumford - 03)
CREATED AT 30/08/2017 14:30:01
REPORT REFERENCE NUMBER 0813-1928-0100-0370-3976
Source file Q3 2017.csv
Address display 6 STANLEY GARDENS , MADDISTON , FALKIRK
Nation scotland