Energy Performance Certificate
2F2 , 7 SOUTH OXFORD STREET , EDINBURGH, EH8 9QF
Energy rating
Current: 64 D | Potential: 81 B
Environmental impact (CO₂)
Current: 46
| Potential: 71
| Field | Value |
|---|---|
| Id | 2287273 |
| BUILDING REFERENCE NUMBER | 1000512700 |
| OSG REFERENCE NUMBER | 906363328 |
| ADDRESS1 | 2F2 |
| ADDRESS2 | 7 SOUTH OXFORD STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH8 9QF |
| INSPECTION DATE | 2019-01-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2019-02-08 |
| ENERGY CONSUMPTION CURRENT | 425.00 |
| TOTAL FLOOR AREA | 73 |
| 3 YR ENERGY COST CURRENT | 3060.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1461.0000 |
| CURRENT ENERGY EFFICIENCY | 64 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 46 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 71 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 72.00 |
| IMPROVEMENTS | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 44; Energy Rating after improvement: B 81; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 345; Energy Rating after improvement: C 76; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 13; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: High heat retention storage heaters; Indicative Cost: £1,600 - £2,400; Typical Saving: 85; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Partial double glazing |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 83% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.20 |
| CO2 EMISSIONS POTENTIAL | 2.50 |
| HEATING COST CURRENT | 2232.0000 |
| HEATING COST POTENTIAL | 837.0000 |
| HOT WATER COST CURRENT | 609.00 |
| HOT WATER COST POTENTIAL | 543.00 |
| LIGHTING COST CURRENT | 219.00 |
| LIGHTING COST POTENTIAL | 219.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 7608 |
| WATER HEATING DEMAND | 2069 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -3563 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.1 |
| DATA ZONE | S01002028 (Dalkeith Rd) |
| ENERGY CONSUMPTION POTENTIAL | 221.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| LOW ENERGY LIGHTING | 83.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 65 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 8.65 |
| CONSTITUENCY | 00QPMQ |
| CONSTITUENCY LABEL | Southside/Newington |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008601 (Newington and Dalkeith Road - 03) |
| CREATED AT | 08/02/2019 12:48:08 |
| REPORT REFERENCE NUMBER | 0500-1107-0229-0070-1913 |
| Source file | Q1 2019.csv |
| Address display | 2F2 , 7 SOUTH OXFORD STREET , EDINBURGH |
| Nation | scotland |