Energy Performance Certificate

145 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL, ML4 3EX

EPC Report

Energy rating

Current: 69 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 66 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 86 Potential: 86
Field Value
Id 2333619
BUILDING REFERENCE NUMBER 1001432520
OSG REFERENCE NUMBER 118117302
ADDRESS1 145 ROCKBURN CRESCENT
ADDRESS2 HATTONRIGG
ADDRESS3 BELLSHILL
POSTCODE ML4 3EX
INSPECTION DATE 2020-02-14
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2020-02-21
ENERGY CONSUMPTION CURRENT 243.00
TOTAL FLOOR AREA 71
3 YR ENERGY COST CURRENT 2076.0000
3 YR ENERGY SAVINGS POTENTIAL 417.0000
CURRENT ENERGY EFFICIENCY 69
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 87
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 66
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 86
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 43.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 26; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 31; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 81; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 297; Energy Rating after improvement: B 87; Environmental Rating after improvement: B 86; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.00
CO2 EMISSIONS POTENTIAL 1.60
HEATING COST CURRENT 1650.0000
HEATING COST POTENTIAL 1311.0000
HOT WATER COST CURRENT 252.00
HOT WATER COST POTENTIAL 174.00
LIGHTING COST CURRENT 174.00
LIGHTING COST POTENTIAL 174.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 9800
WATER HEATING DEMAND 1887
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -1858
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 2.4
DATA ZONE S01004685 (Hattonrigg)
ENERGY CONSUMPTION POTENTIAL 111.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL North Lanarkshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QZMP
CONSTITUENCY LABEL Bellshill
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01011528 (Bellshill Central - 01)
CREATED AT 21/02/2020 17:27:27
REPORT REFERENCE NUMBER 0400-3345-0222-5192-1203
Source file Q1 2020.csv
Address display 145 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL
Nation scotland