Energy Performance Certificate
42 SOUTH GYLE WYND , EDINBURGH, EH12 9HJ
Energy rating
Current: 60 D | Potential: 68 D
Environmental impact (CO₂)
Current: 56
| Potential: 67
| Field | Value |
|---|---|
| Id | 2646605 |
| BUILDING REFERENCE NUMBER | 1001139635 |
| OSG REFERENCE NUMBER | 906228553 |
| ADDRESS1 | 42 SOUTH GYLE WYND |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2018-04-14 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2018-04-18 |
| ENERGY CONSUMPTION CURRENT | 388.00 |
| TOTAL FLOOR AREA | 44 |
| 3 YR ENERGY COST CURRENT | 2034.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 456.0000 |
| CURRENT ENERGY EFFICIENCY | 60 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 68 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 56 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 67 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 68.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £10; Typical Saving: 10; Energy Rating after improvement: D 61; Environmental Rating after improvement: D 57; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 40; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 13; Energy Rating after improvement: D 60; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 89; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | To unheated space, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 67% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.00 |
| CO2 EMISSIONS POTENTIAL | 0.80 |
| HEATING COST CURRENT | 1404.0000 |
| HEATING COST POTENTIAL | 1173.0000 |
| HOT WATER COST CURRENT | 489.00 |
| HOT WATER COST POTENTIAL | 300.00 |
| LIGHTING COST CURRENT | 141.00 |
| LIGHTING COST POTENTIAL | 105.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6004 |
| WATER HEATING DEMAND | 2603 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | 2.36 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 287.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 67.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 18/04/2018 08:53:15 |
| REPORT REFERENCE NUMBER | 0160-2594-3140-9398-1151 |
| Source file | Q2 2018.csv |
| Address display | 42 SOUTH GYLE WYND , EDINBURGH |
| Nation | scotland |