Energy Performance Certificate
4F1 , 4 SOUTH OXFORD STREET , EDINBURGH, EH8 9QF
Energy rating
Current: 58 D | Potential: 75 C
Environmental impact (CO₂)
Current: 51
| Potential: 73
| Field | Value |
|---|---|
| Id | 2323740 |
| BUILDING REFERENCE NUMBER | 1000512673 |
| OSG REFERENCE NUMBER | 906363301 |
| ADDRESS1 | 4F1 |
| ADDRESS2 | 4 SOUTH OXFORD STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH8 9QF |
| INSPECTION DATE | 2020-02-19 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-02-20 |
| ENERGY CONSUMPTION CURRENT | 336.00 |
| TOTAL FLOOR AREA | 84 |
| 3 YR ENERGY COST CURRENT | 3183.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1287.0000 |
| CURRENT ENERGY EFFICIENCY | 58 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 75 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 51 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 73 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 59.00 |
| IMPROVEMENTS | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 39; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 27; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Flat roof insulation; Indicative Cost: £850 - £1,500; Typical Saving: 363; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Solid brick, as built, no insulation (assumed) | Timber frame, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Very Poor |
| WALL ENV EFF | Poor | Very Poor |
| ROOF DESCRIPTION | Flat, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Mostly double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 86% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.00 |
| CO2 EMISSIONS POTENTIAL | 2.30 |
| HEATING COST CURRENT | 2679.0000 |
| HEATING COST POTENTIAL | 1392.0000 |
| HOT WATER COST CURRENT | 267.00 |
| HOT WATER COST POTENTIAL | 267.00 |
| LIGHTING COST CURRENT | 237.00 |
| LIGHTING COST POTENTIAL | 237.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 16381 |
| WATER HEATING DEMAND | 1996 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -681 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.85 |
| DATA ZONE | S01002028 (Dalkeith Rd) |
| ENERGY CONSUMPTION POTENTIAL | 180.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 86.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 04 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 95 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 7.9 |
| CONSTITUENCY | 00QPMQ |
| CONSTITUENCY LABEL | Southside/Newington |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008601 (Newington and Dalkeith Road - 03) |
| CREATED AT | 20/02/2020 07:56:06 |
| REPORT REFERENCE NUMBER | 0160-2321-7020-2190-2571 |
| Source file | Q1 2020.csv |
| Address display | 4F1 , 4 SOUTH OXFORD STREET , EDINBURGH |
| Nation | scotland |