Energy Performance Certificate
124 RAEMOIR AVENUE , BANCHORY, AB31 5UF
Energy rating
Current: 46 E | Potential: 88 B
Environmental impact (CO₂)
Current: 52
| Potential: 72
| Field | Value |
|---|---|
| Id | 3054162 |
| BUILDING REFERENCE NUMBER | 1000921565 |
| OSG REFERENCE NUMBER | 151038906 |
| ADDRESS1 | 124 RAEMOIR AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | BANCHORY |
| POSTCODE | AB31 5UF |
| INSPECTION DATE | 2019-07-09 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2019-07-09 |
| ENERGY CONSUMPTION CURRENT | 415.00 |
| TOTAL FLOOR AREA | 70 |
| 3 YR ENERGY COST CURRENT | 4983.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2640.0000 |
| CURRENT ENERGY EFFICIENCY | 46 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 88 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 52 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 72 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 70.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 163; Energy Rating after improvement: E 52; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 32; Energy Rating after improvement: E 53; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: High heat retention storage heaters; Indicative Cost: £1,600 - £2,400; Typical Saving: 616; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 292; Energy Rating after improvement: B 88; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 66; Energy Rating after improvement: C 76; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.90 |
| CO2 EMISSIONS POTENTIAL | 1.70 |
| HEATING COST CURRENT | 3651.0000 |
| HEATING COST POTENTIAL | 1839.0000 |
| HOT WATER COST CURRENT | 1167.00 |
| HOT WATER COST POTENTIAL | 324.00 |
| LIGHTING COST CURRENT | 165.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6928 |
| WATER HEATING DEMAND | 2213 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.26 |
| DATA ZONE | S01000317 (Banchory) |
| ENERGY CONSUMPTION POTENTIAL | 271.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 1 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2602 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMR |
| CONSTITUENCY LABEL | Banchory and Mid Deeside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01006860 (Banchory East - 02) |
| CREATED AT | 09/07/2019 16:39:21 |
| REPORT REFERENCE NUMBER | 0150-2511-6030-9201-2931 |
| Source file | Q3 2019.csv |
| Address display | 124 RAEMOIR AVENUE , BANCHORY |
| Nation | scotland |