Energy Performance Certificate
89 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL, ML4 3EX
Energy rating
Current: 72 C | Potential: 76 C
Environmental impact (CO₂)
Current: 74
| Potential: 79
| Field | Value |
|---|---|
| Id | 3225124 |
| BUILDING REFERENCE NUMBER | 1001432538 |
| OSG REFERENCE NUMBER | 118117322 |
| ADDRESS1 | 89 ROCKBURN CRESCENT |
| ADDRESS2 | HATTONRIGG |
| ADDRESS3 | BELLSHILL |
| POSTCODE | ML4 3EX |
| INSPECTION DATE | 2023-09-01 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-09-04 |
| ENERGY CONSUMPTION CURRENT | 225.00 |
| TOTAL FLOOR AREA | 48 |
| 3 YR ENERGY COST CURRENT | 3174.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 534.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 76 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 74 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 40.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 42; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 79; Green Deal Eligible: N | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 135; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) | Cavity wall, filled cavity |
| WALL ENERGY EFF | Average | Average |
| WALL ENV EFF | Average | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 40% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.90 |
| CO2 EMISSIONS POTENTIAL | 0.40 |
| HEATING COST CURRENT | 2181.0000 |
| HEATING COST POTENTIAL | 1794.0000 |
| HOT WATER COST CURRENT | 600.00 |
| HOT WATER COST POTENTIAL | 600.00 |
| LIGHTING COST CURRENT | 393.00 |
| LIGHTING COST POTENTIAL | 246.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4955 |
| WATER HEATING DEMAND | 1663 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -294 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01004685 (Hattonrigg) |
| ENERGY CONSUMPTION POTENTIAL | 184.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 5 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| LOW ENERGY LIGHTING | 40.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | North Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 6.64 |
| CONSTITUENCY | 00QZMP |
| CONSTITUENCY LABEL | Bellshill |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01011528 (Bellshill Central - 01) |
| CREATED AT | 04/09/2023 09:05:23 |
| REPORT REFERENCE NUMBER | 0098-1014-3201-5527-3204 |
| Source file | Q3 2023.csv |
| Address display | 89 ROCKBURN CRESCENT , HATTONRIGG , BELLSHILL |
| Nation | scotland |