Energy Performance Certificate
128 SOUTH GYLE WYND , EDINBURGH, EH12 9HJ
Energy rating
Current: 69 C | Potential: 88 B
Environmental impact (CO₂)
Current: 67
| Potential: 88
| Field | Value |
|---|---|
| Id | 3482984 |
| BUILDING REFERENCE NUMBER | 1001139623 |
| OSG REFERENCE NUMBER | 906228409 |
| ADDRESS1 | 128 SOUTH GYLE WYND |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH12 9HJ |
| INSPECTION DATE | 2020-10-05 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-10-16 |
| ENERGY CONSUMPTION CURRENT | 263.00 |
| TOTAL FLOOR AREA | 55 |
| 3 YR ENERGY COST CURRENT | 1803.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 366.0000 |
| CURRENT ENERGY EFFICIENCY | 69 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 88 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 67 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 88 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 46.00 |
| IMPROVEMENTS | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 22; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 25; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 315; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 88; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 55; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Draughtproofing; Indicative Cost: £80 - £120; Typical Saving: 20; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 150 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.60 |
| CO2 EMISSIONS POTENTIAL | 1.60 |
| HEATING COST CURRENT | 1422.0000 |
| HEATING COST POTENTIAL | 1128.0000 |
| HOT WATER COST CURRENT | 240.00 |
| HOT WATER COST POTENTIAL | 168.00 |
| LIGHTING COST CURRENT | 141.00 |
| LIGHTING COST POTENTIAL | 141.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 7181 |
| WATER HEATING DEMAND | 1802 |
| IMPACT LOFT INSULATION | -171 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.39 |
| DATA ZONE | S01001995 (South Gyle) |
| ENERGY CONSUMPTION POTENTIAL | 101.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMC |
| CONSTITUENCY LABEL | Drum Brae/Gyle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01008989 (South Gyle - 03) |
| CREATED AT | 16/10/2020 16:53:02 |
| REPORT REFERENCE NUMBER | 0053-1911-2200-6290-3204 |
| Source file | Q4 2020.csv |
| Address display | 128 SOUTH GYLE WYND , EDINBURGH |
| Nation | scotland |