Energy Performance Certificate

5 Upper Terrace, NW3 6RH

EPC Report

Energy rating

Current: 56 D | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 48 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 51 Potential: 51
Field Value
LMK KEY ec464f9f73e2fbc1082cbc2e05bc843aff589cf24009d89dd11a67e1efef9315
ADDRESS1 5 Upper Terrace
ADDRESS2
ADDRESS3
POSTCODE NW3 6RH
BUILDING REFERENCE NUMBER 10007339897
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-03-07
LOCAL AUTHORITY E09000007
CONSTITUENCY E14001265
COUNTY
LODGEMENT DATE 2025-03-26
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 228
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 17.0
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 15.0
LIGHTING COST CURRENT 255
LIGHTING COST POTENTIAL 255
HEATING COST CURRENT 5015
HEATING COST POTENTIAL 4844
HOT WATER COST CURRENT 213
HOT WATER COST POTENTIAL 213
TOTAL FLOOR AREA 421.0
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, with external insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0.0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 5 Upper Terrace
LOCAL AUTHORITY LABEL Camden
CONSTITUENCY LABEL
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2025-03-26 22:24:46
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 85
LOW ENERGY FIXED LIGHT COUNT
UPRN 5105947
UPRN SOURCE Energy Assessor
REPORT TYPE 100
Address display
Nation ew