Energy Performance Certificate
7 Tregunter Road, SW10 9LS
Energy rating
Current: 73 C | Potential: 78 C
Environmental impact (CO₂)
Current: 64
| Potential: 70
| Field | Value |
|---|---|
| LMK KEY | 96cf5e3790e1f603530118df38d0914e6c9f4096e35150359ff89a80a84355de |
| ADDRESS1 | 7 Tregunter Road |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | SW10 9LS |
| BUILDING REFERENCE NUMBER | 10004036688 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 73 |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| PROPERTY TYPE | House |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2023-02-03 |
| LOCAL AUTHORITY | E09000020 |
| CONSTITUENCY | E14000629 |
| COUNTY | — |
| LODGEMENT DATE | 2023-02-13 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 64 |
| ENVIRONMENT IMPACT POTENTIAL | 70 |
| ENERGY CONSUMPTION CURRENT | 124 |
| ENERGY CONSUMPTION POTENTIAL | 97 |
| CO2 EMISSIONS CURRENT | 25.2 |
| CO2 EMISS CURR PER FLOOR AREA | 22 |
| CO2 EMISSIONS POTENTIAL | 19.8 |
| LIGHTING COST CURRENT | 439 |
| LIGHTING COST POTENTIAL | 439 |
| HEATING COST CURRENT | 4114 |
| HEATING COST POTENTIAL | 3338 |
| HOT WATER COST CURRENT | 162 |
| HOT WATER COST POTENTIAL | 162 |
| TOTAL FLOOR AREA | 1153.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | — |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 13 |
| NUMBER HEATED ROOMS | 13 |
| LOW ENERGY LIGHTING | 75 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated at rafters |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.9 |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 7 Tregunter Road |
| LOCAL AUTHORITY LABEL | Kensington and Chelsea |
| CONSTITUENCY LABEL | Chelsea and Fulham |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2023-02-13 07:16:27 |
| TENURE | Owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 64 |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 217087654 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |