Energy Performance Certificate
Hamilton House, Old Avenue, KT13 0QE
Energy rating
Current: 94 A | Potential: 98 A
Environmental impact (CO₂)
Current: 80
| Potential: 85
| Field | Value |
|---|---|
| LMK KEY | 892a208e5e2bf63e32e1323481152f9e5e092eb19b0c6c5649816728b8d20a93 |
| ADDRESS1 | Hamilton House |
| ADDRESS2 | Old Avenue |
| ADDRESS3 | — |
| POSTCODE | KT13 0QE |
| BUILDING REFERENCE NUMBER | 5693318868 |
| CURRENT ENERGY RATING | A |
| POTENTIAL ENERGY RATING | A |
| CURRENT ENERGY EFFICIENCY | 94 |
| POTENTIAL ENERGY EFFICIENCY | 98 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2022-05-24 |
| LOCAL AUTHORITY | E07000207 |
| CONSTITUENCY | E14000907 |
| COUNTY | Surrey |
| LODGEMENT DATE | 2022-05-25 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 80 |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| ENERGY CONSUMPTION CURRENT | 42 |
| ENERGY CONSUMPTION POTENTIAL | 21 |
| CO2 EMISSIONS CURRENT | 8.1 |
| CO2 EMISS CURR PER FLOOR AREA | 8 |
| CO2 EMISSIONS POTENTIAL | 4.5 |
| LIGHTING COST CURRENT | 294 |
| LIGHTING COST POTENTIAL | 294 |
| HEATING COST CURRENT | 7189 |
| HEATING COST POTENTIAL | 6907 |
| HOT WATER COST CURRENT | 171 |
| HOT WATER COST POTENTIAL | 171 |
| TOTAL FLOOR AREA | 976.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | — |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 2 |
| NUMBER HABITABLE ROOMS | 17 |
| NUMBER HEATED ROOMS | 17 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Cavity wall, with external insulation |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.41 |
| PHOTO SUPPLY | 100.0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ADDRESS | Hamilton House, Old Avenue |
| LOCAL AUTHORITY LABEL | Elmbridge |
| CONSTITUENCY LABEL | Runnymede and Weybridge |
| POSTTOWN | WEYBRIDGE |
| CONSTRUCTION AGE BAND | England and Wales: 1983-1990 |
| LODGEMENT DATETIME | 2022-05-25 10:32:21 |
| TENURE | Owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 110 |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 100061346458 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |