Energy Performance Certificate
Hillside, West Road, KT13 0LZ
Energy rating
Current: 67 D | Potential: 69 C
Environmental impact (CO₂)
Current: 62
| Potential: 64
| Field | Value |
|---|---|
| LMK KEY | 841615429062012100216475522228652 |
| ADDRESS1 | Hillside |
| ADDRESS2 | West Road |
| ADDRESS3 | — |
| POSTCODE | KT13 0LZ |
| BUILDING REFERENCE NUMBER | 5298212078 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 67 |
| POTENTIAL ENERGY EFFICIENCY | 69 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2012-10-02 |
| LOCAL AUTHORITY | E07000207 |
| CONSTITUENCY | E14000907 |
| COUNTY | Surrey |
| LODGEMENT DATE | 2012-10-02 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 62 |
| ENVIRONMENT IMPACT POTENTIAL | 64 |
| ENERGY CONSUMPTION CURRENT | 148 |
| ENERGY CONSUMPTION POTENTIAL | 142 |
| CO2 EMISSIONS CURRENT | 33.0 |
| CO2 EMISS CURR PER FLOOR AREA | 28 |
| CO2 EMISSIONS POTENTIAL | 31.0 |
| LIGHTING COST CURRENT | 417 |
| LIGHTING COST POTENTIAL | 239 |
| HEATING COST CURRENT | 6095 |
| HEATING COST POTENTIAL | 6121 |
| HOT WATER COST CURRENT | 111 |
| HOT WATER COST POTENTIAL | 111 |
| TOTAL FLOOR AREA | 1181.0 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | NODATA! |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | 2110 |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 13 |
| NUMBER HEATED ROOMS | 13 |
| LOW ENERGY LIGHTING | 25 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in 25% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | NO DATA! |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | — |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ADDRESS | Hillside, West Road |
| LOCAL AUTHORITY LABEL | Elmbridge |
| CONSTITUENCY LABEL | Runnymede and Weybridge |
| POSTTOWN | WEYBRIDGE |
| CONSTRUCTION AGE BAND | England and Wales: 2007 onwards |
| LODGEMENT DATETIME | 2012-10-02 16:47:55 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 100 |
| LOW ENERGY FIXED LIGHT COUNT | 25 |
| UPRN | 100061348207 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |