Energy Performance Certificate

37, Victoria Road, W8 5RF

EPC Report

Energy rating

Current: 73 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 64 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 67 Potential: 67
Field Value
LMK KEY 813187839962015111921314220318915
ADDRESS1 37, Victoria Road
ADDRESS2
ADDRESS3
POSTCODE W8 5RF
BUILDING REFERENCE NUMBER 1214310078
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-11-19
LOCAL AUTHORITY E09000020
CONSTITUENCY E14000768
COUNTY Greater London Authority
LODGEMENT DATE 2015-11-19
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 129
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 12.0
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 11.0
LIGHTING COST CURRENT 322
LIGHTING COST POTENTIAL 161
HEATING COST CURRENT 2174
HEATING COST POTENTIAL 2209
HOT WATER COST CURRENT 170
HOT WATER COST POTENTIAL 170
TOTAL FLOOR AREA 546.0
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2110
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF NO DATA!
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 37, Victoria Road
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Kensington
POSTTOWN LONDON
CONSTRUCTION AGE BAND INVALID!
LODGEMENT DATETIME 2015-11-19 21:31:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 217089024
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew