Energy Performance Certificate
65 Carisbrooke Avenue, Chelmsley Wood, B37 7SG
Energy rating
Current: 82 B | Potential: 93 A
Environmental impact (CO₂)
Current: 85
| Potential: 95
| Field | Value |
|---|---|
| LMK KEY | 7f2f9bf61bc362932e9cba9fa133bdf871b7e549a35dc9c3226c55870b6f77dc |
| ADDRESS1 | 65 Carisbrooke Avenue |
| ADDRESS2 | Chelmsley Wood |
| ADDRESS3 | — |
| POSTCODE | B37 7SG |
| BUILDING REFERENCE NUMBER | 10007824032 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | A |
| CURRENT ENERGY EFFICIENCY | 82 |
| POTENTIAL ENERGY EFFICIENCY | 93 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2024-04-22 |
| LOCAL AUTHORITY | E08000029 |
| CONSTITUENCY | E14001358 |
| COUNTY | — |
| LODGEMENT DATE | 2025-06-09 |
| TRANSACTION TYPE | rental |
| ENVIRONMENT IMPACT CURRENT | 85 |
| ENVIRONMENT IMPACT POTENTIAL | 95 |
| ENERGY CONSUMPTION CURRENT | 100 |
| ENERGY CONSUMPTION POTENTIAL | 27 |
| CO2 EMISSIONS CURRENT | 1.3 |
| CO2 EMISS CURR PER FLOOR AREA | 18 |
| CO2 EMISSIONS POTENTIAL | 0.4 |
| LIGHTING COST CURRENT | 84 |
| LIGHTING COST POTENTIAL | 84 |
| HEATING COST CURRENT | 342 |
| HEATING COST POTENTIAL | 342 |
| HOT WATER COST CURRENT | 89 |
| HOT WATER COST POTENTIAL | 89 |
| TOTAL FLOOR AREA | 74.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | — |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system, plus solar |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | Y |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 65 Carisbrooke Avenue, Chelmsley Wood |
| LOCAL AUTHORITY LABEL | Solihull |
| CONSTITUENCY LABEL | — |
| POSTTOWN | Solihull |
| CONSTRUCTION AGE BAND | England and Wales: 2007-2011 |
| LODGEMENT DATETIME | 2025-06-09 13:23:09 |
| TENURE | Rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 10023647483 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |