Energy Performance Certificate

55, Shakespeare Road, PO1 5LE

EPC Report

Energy rating

Current: 14 G | Potential: 19 G
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 G Current: 14 G 19 G Potential: 19 G

Environmental impact (CO₂)

Current: 26 | Potential: 30
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 30 Potential: 30
Field Value
LMK KEY 746507219022012020616535795468742
ADDRESS1 55, Shakespeare Road
ADDRESS2
ADDRESS3
POSTCODE PO1 5LE
BUILDING REFERENCE NUMBER 4902135968
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING G
CURRENT ENERGY EFFICIENCY 14
POTENTIAL ENERGY EFFICIENCY 19
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-02-06
LOCAL AUTHORITY E06000044
CONSTITUENCY E14000884
COUNTY
LODGEMENT DATE 2012-02-06
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 30
ENERGY CONSUMPTION CURRENT 651
ENERGY CONSUMPTION POTENTIAL 591
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 115
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 37
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 1385
HEATING COST POTENTIAL 1214
HOT WATER COST CURRENT 418
HOT WATER COST POTENTIAL 418
TOTAL FLOOR AREA 64.8
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2699
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0.0
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION natural
ADDRESS 55, Shakespeare Road
LOCAL AUTHORITY LABEL Portsmouth
CONSTITUENCY LABEL Portsmouth South
POSTTOWN PORTSMOUTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-02-06 16:53:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 1775072683
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew