Energy Performance Certificate

Spur Point, Marley Heights, GU27 3LU

EPC Report

Energy rating

Current: 32 F | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 30 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 57 Potential: 57
Field Value
LMK KEY 717544441312011103123020599799799
ADDRESS1 Spur Point
ADDRESS2 Marley Heights
ADDRESS3
POSTCODE GU27 3LU
BUILDING REFERENCE NUMBER 7957192968
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2011-10-30
LOCAL AUTHORITY E07000225
CONSTITUENCY E14000633
COUNTY West Sussex
LODGEMENT DATE 2011-10-31
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 328
ENERGY CONSUMPTION POTENTIAL 184
CO2 EMISSIONS CURRENT 21.0
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 11.0
LIGHTING COST CURRENT 163
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 3858
HEATING COST POTENTIAL 2141
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 167
TOTAL FLOOR AREA 304.75
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2106
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 24
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system, no cylinderstat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 24% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0.0
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION natural
ADDRESS Spur Point, Marley Heights
LOCAL AUTHORITY LABEL Chichester
CONSTITUENCY LABEL Chichester
POSTTOWN HASLEMERE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2011-10-31 23:02:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 33
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100062340498
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display