Energy Performance Certificate

West Lodge, West Drive, SL5 0LF

EPC Report

Energy rating

Current: 72 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 75 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 76 Potential: 76
Field Value
LMK KEY 640249290532015102014265169268298
ADDRESS1 West Lodge
ADDRESS2 West Drive
ADDRESS3
POSTCODE SL5 0LF
BUILDING REFERENCE NUMBER 9899247868
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM NO DATA!
INSPECTION DATE 2015-10-20
LOCAL AUTHORITY E07000212
CONSTITUENCY E14000907
COUNTY Surrey
LODGEMENT DATE 2015-10-20
TRANSACTION TYPE new dwelling
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 101
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 16.0
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 15.0
LIGHTING COST CURRENT 214
LIGHTING COST POTENTIAL 214
HEATING COST CURRENT 4081
HEATING COST POTENTIAL 4081
HOT WATER COST CURRENT 366
HOT WATER COST POTENTIAL 366
TOTAL FLOOR AREA 941.0
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL NO DATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS
MULTI GLAZE PROPORTION
GLAZED TYPE NO DATA!
GLAZED AREA NO DATA!
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m-¦K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m-¦K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.18 W/m-¦K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, Underfloor heating and radiators, pipes in screed above insulation, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION NO DATA!
ADDRESS West Lodge, West Drive
LOCAL AUTHORITY LABEL Runnymede
CONSTITUENCY LABEL Runnymede and Weybridge
POSTTOWN ASCOT
CONSTRUCTION AGE BAND NO DATA!
LODGEMENT DATETIME 2015-10-20 14:26:51
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 75
LOW ENERGY FIXED LIGHT COUNT 75
UPRN 100061508186
UPRN SOURCE Address Matched
REPORT TYPE 101
Address display
Nation ew