Energy Performance Certificate

12, Kensington Gate, W8 5NA

EPC Report

Energy rating

Current: 58 D | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 46 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 60 Potential: 60
Field Value
LMK KEY 56815749962019061019155763208491
ADDRESS1 12, Kensington Gate
ADDRESS2
ADDRESS3
POSTCODE W8 5NA
BUILDING REFERENCE NUMBER 9626493468
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-06-10
LOCAL AUTHORITY E09000020
CONSTITUENCY E14000768
COUNTY Greater London Authority
LODGEMENT DATE 2019-06-10
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 213
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 14.0
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 9.3
LIGHTING COST CURRENT 229
LIGHTING COST POTENTIAL 137
HEATING COST CURRENT 2283
HEATING COST POTENTIAL 1721
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 156
TOTAL FLOOR AREA 362.0
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2106
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 32
NUMBER OPEN FIREPLACES 4
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF NO DATA!
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 32% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Kensington Gate
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Kensington
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-06-10 19:15:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 217043987
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew