Energy Performance Certificate
The Coach House, 44 Frognal Lane, NW3 6PP
Energy rating
Current: 47 E | Potential: 61 D
Environmental impact (CO₂)
Current: 39
| Potential: 51
| Field | Value |
|---|---|
| LMK KEY | 554760307412011112817015998299489 |
| ADDRESS1 | The Coach House |
| ADDRESS2 | 44 Frognal Lane |
| ADDRESS3 | — |
| POSTCODE | NW3 6PP |
| BUILDING REFERENCE NUMBER | 4913780868 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 47 |
| POTENTIAL ENERGY EFFICIENCY | 61 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2011-11-28 |
| LOCAL AUTHORITY | E09000007 |
| CONSTITUENCY | E14000727 |
| COUNTY | Greater London Authority |
| LODGEMENT DATE | 2011-11-28 |
| TRANSACTION TYPE | rental (private) |
| ENVIRONMENT IMPACT CURRENT | 39 |
| ENVIRONMENT IMPACT POTENTIAL | 51 |
| ENERGY CONSUMPTION CURRENT | 275 |
| ENERGY CONSUMPTION POTENTIAL | 204 |
| CO2 EMISSIONS CURRENT | 31.0 |
| CO2 EMISS CURR PER FLOOR AREA | 53 |
| CO2 EMISSIONS POTENTIAL | 23.0 |
| LIGHTING COST CURRENT | 260 |
| LIGHTING COST POTENTIAL | 137 |
| HEATING COST CURRENT | 5086 |
| HEATING COST POTENTIAL | 3834 |
| HOT WATER COST CURRENT | 163 |
| HOT WATER COST POTENTIAL | 124 |
| TOTAL FLOOR AREA | 580.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | NODATA! |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | 2104 |
| MULTI GLAZE PROPORTION | 10 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 8 |
| NUMBER HEATED ROOMS | 8 |
| LOW ENERGY LIGHTING | 10 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Some double glazing |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 150 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 10% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | NO DATA! |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.6 |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | natural |
| ADDRESS | The Coach House, 44 Frognal Lane |
| LOCAL AUTHORITY LABEL | Camden |
| CONSTITUENCY LABEL | Hampstead and Kilburn |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2011-11-28 17:01:59 |
| TENURE | rental (private) |
| FIXED LIGHTING OUTLETS COUNT | 20 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| UPRN | 5185011 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |