Energy Performance Certificate

60, Regents Park Road, NW1 7SX

EPC Report

Energy rating

Current: 32 F | Potential: 37 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 37 F Potential: 37 F

Environmental impact (CO₂)

Current: 33 | Potential: 38
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 38 Potential: 38
Field Value
LMK KEY 486467429922010051821134026488280
ADDRESS1 60, Regents Park Road
ADDRESS2
ADDRESS3
POSTCODE NW1 7SX
BUILDING REFERENCE NUMBER 8262206768
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 37
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2010-05-18
LOCAL AUTHORITY E09000007
CONSTITUENCY E14000750
COUNTY Greater London Authority
LODGEMENT DATE 2010-05-18
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 38
ENERGY CONSUMPTION CURRENT 395
ENERGY CONSUMPTION POTENTIAL 356
CO2 EMISSIONS CURRENT 20.0
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 20.0
LIGHTING COST CURRENT 294
LIGHTING COST POTENTIAL 167
HEATING COST CURRENT 3029
HEATING COST POTENTIAL 3068
HOT WATER COST CURRENT 468
HOT WATER COST POTENTIAL 200
TOTAL FLOOR AREA 312.04
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL NO DATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2106
MULTI GLAZE PROPORTION 20
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 24
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 24% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas - this is for backwards compatibility only and should not be used
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0.0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 60, Regents Park Road
LOCAL AUTHORITY LABEL Camden
CONSTITUENCY LABEL Holborn and St Pancras
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2010-05-18 21:13:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 5167656
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew