Energy Performance Certificate
108 Panorama Road, Sandbanks, BH13 7RG
Energy rating
Current: 81 B | Potential: 83 B
Environmental impact (CO₂)
Current: 82
| Potential: 83
| Field | Value |
|---|---|
| LMK KEY | 407612980062009120310013640478581 |
| ADDRESS1 | 108 Panorama Road |
| ADDRESS2 | Sandbanks |
| ADDRESS3 | — |
| POSTCODE | BH13 7RG |
| BUILDING REFERENCE NUMBER | 8452840768 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2009-12-03 |
| LOCAL AUTHORITY | E06000058 |
| CONSTITUENCY | E14000881 |
| COUNTY | — |
| LODGEMENT DATE | 2009-12-03 |
| TRANSACTION TYPE | new dwelling |
| ENVIRONMENT IMPACT CURRENT | 82 |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| ENERGY CONSUMPTION CURRENT | 88 |
| ENERGY CONSUMPTION POTENTIAL | 84 |
| CO2 EMISSIONS CURRENT | 8.5 |
| CO2 EMISS CURR PER FLOOR AREA | 14 |
| CO2 EMISSIONS POTENTIAL | 8.2 |
| LIGHTING COST CURRENT | 431 |
| LIGHTING COST POTENTIAL | 324 |
| HEATING COST CURRENT | 1084 |
| HEATING COST POTENTIAL | 1099 |
| HOT WATER COST CURRENT | 200 |
| HOT WATER COST POTENTIAL | 200 |
| TOTAL FLOOR AREA | 589.31 |
| ENERGY TARIFF | off-peak 7 hour |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | NO DATA! |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | 2110 |
| MULTI GLAZE PROPORTION | — |
| GLAZED TYPE | NO DATA! |
| GLAZED AREA | NO DATA! |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | — |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.18 W/m?K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.29 W/m?K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.18 W/m?K |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Very Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 67% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| MAIN FUEL | mains gas - this is for backwards compatibility only and should not be used |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | NO DATA! |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.7 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | NO DATA! |
| ADDRESS | 108 Panorama Road, Sandbanks |
| LOCAL AUTHORITY LABEL | Bournemouth, Christchurch and Poole |
| CONSTITUENCY LABEL | Poole |
| POSTTOWN | POOLE |
| CONSTRUCTION AGE BAND | NO DATA! |
| LODGEMENT DATETIME | 2009-12-03 10:01:36 |
| TENURE | — |
| FIXED LIGHTING OUTLETS COUNT | — |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 10023692165 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 101 |
| Address display | — |
| Nation | ew |