Energy Performance Certificate

85, Elgin Crescent, W11 2JF

EPC Report

Energy rating

Current: 42 E | Potential: 56 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 56 D Potential: 56 D

Environmental impact (CO₂)

Current: 38 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 49 Potential: 49
Field Value
LMK KEY 267971724212009042122511107210565
ADDRESS1 85, Elgin Crescent
ADDRESS2
ADDRESS3
POSTCODE W11 2JF
BUILDING REFERENCE NUMBER 5596470668
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 56
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2009-04-21
LOCAL AUTHORITY E09000020
CONSTITUENCY E14000768
COUNTY Greater London Authority
LODGEMENT DATE 2009-04-21
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 352
ENERGY CONSUMPTION POTENTIAL 269
CO2 EMISSIONS CURRENT 17.0
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 13.0
LIGHTING COST CURRENT 304
LIGHTING COST POTENTIAL 152
HEATING COST CURRENT 2116
HEATING COST POTENTIAL 1697
HOT WATER COST CURRENT 242
HOT WATER COST POTENTIAL 183
TOTAL FLOOR AREA 229.8
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL NO DATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2104
MULTI GLAZE PROPORTION 21
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas - this is for backwards compatibility only and should not be used
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0.0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 85, Elgin Crescent
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Kensington
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2009-04-21 22:51:11
TENURE rental (private)
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 217028403
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew