Energy Performance Certificate

38, Clarendon Road, W11 3AD

EPC Report

Energy rating

Current: 70 C | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 59 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 61 Potential: 61
Field Value
LMK KEY 259412629962018020818061850298518
ADDRESS1 38, Clarendon Road
ADDRESS2
ADDRESS3
POSTCODE W11 3AD
BUILDING REFERENCE NUMBER 1500220668
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-01-11
LOCAL AUTHORITY E09000020
CONSTITUENCY E14000768
COUNTY Greater London Authority
LODGEMENT DATE 2018-02-08
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 150
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 16.0
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 15.0
LIGHTING COST CURRENT 199
LIGHTING COST POTENTIAL 199
HEATING COST CURRENT 2790
HEATING COST POTENTIAL 2790
HOT WATER COST CURRENT 160
HOT WATER COST POTENTIAL 160
TOTAL FLOOR AREA 606.0
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2110
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF NO DATA!
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38, Clarendon Road
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Kensington
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-02-08 18:06:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 217015922
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew