Energy Performance Certificate
Flat 1, 32 Hans Road, SW3 1RW
Energy rating
Current: 82 B | Potential: 82 B
Environmental impact (CO₂)
Current: 80
| Potential: 80
| Field | Value |
|---|---|
| LMK KEY | 1526875969062017031615471500288943 |
| ADDRESS1 | Flat 1 |
| ADDRESS2 | 32 Hans Road |
| ADDRESS3 | — |
| POSTCODE | SW3 1RW |
| BUILDING REFERENCE NUMBER | 4069650578 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 82 |
| POTENTIAL ENERGY EFFICIENCY | 82 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2017-03-08 |
| LOCAL AUTHORITY | E09000020 |
| CONSTITUENCY | E14000768 |
| COUNTY | Greater London Authority |
| LODGEMENT DATE | 2017-03-16 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 80 |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| ENERGY CONSUMPTION CURRENT | 88 |
| ENERGY CONSUMPTION POTENTIAL | 88 |
| CO2 EMISSIONS CURRENT | 2.7 |
| CO2 EMISS CURR PER FLOOR AREA | 15 |
| CO2 EMISSIONS POTENTIAL | 2.7 |
| LIGHTING COST CURRENT | 96 |
| LIGHTING COST POTENTIAL | 96 |
| HEATING COST CURRENT | 423 |
| HEATING COST POTENTIAL | 423 |
| HOT WATER COST CURRENT | 138 |
| HOT WATER COST POTENTIAL | 138 |
| TOTAL FLOOR AREA | 175.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | Ground |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | 2110 |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, insulated |
| FLOOR ENERGY EFF | NO DATA! |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Solid brick, with internal insulation |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | no corridor |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Flat 1, 32 Hans Road |
| LOCAL AUTHORITY LABEL | Kensington and Chelsea |
| CONSTITUENCY LABEL | Kensington |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2017-03-16 15:47:15 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | — |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 217129055 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |