Energy Performance Certificate
Granville House, Granville Road, KT13 0QL
Energy rating
Current: 57 D | Potential: 60 D
Environmental impact (CO₂)
Current: 59
| Potential: 60
| Field | Value |
|---|---|
| LMK KEY | 119077350142009033121371142817798 |
| ADDRESS1 | Granville House |
| ADDRESS2 | Granville Road |
| ADDRESS3 | — |
| POSTCODE | KT13 0QL |
| BUILDING REFERENCE NUMBER | 3158558468 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 57 |
| POTENTIAL ENERGY EFFICIENCY | 60 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2009-03-31 |
| LOCAL AUTHORITY | E07000207 |
| CONSTITUENCY | E14000907 |
| COUNTY | Surrey |
| LODGEMENT DATE | 2009-03-31 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 59 |
| ENVIRONMENT IMPACT POTENTIAL | 60 |
| ENERGY CONSUMPTION CURRENT | 203 |
| ENERGY CONSUMPTION POTENTIAL | 196 |
| CO2 EMISSIONS CURRENT | 21.0 |
| CO2 EMISS CURR PER FLOOR AREA | 33 |
| CO2 EMISSIONS POTENTIAL | 20.0 |
| LIGHTING COST CURRENT | 592 |
| LIGHTING COST POTENTIAL | 296 |
| HEATING COST CURRENT | 2672 |
| HEATING COST POTENTIAL | 2750 |
| HOT WATER COST CURRENT | 165 |
| HOT WATER COST POTENTIAL | 165 |
| TOTAL FLOOR AREA | 675.3 |
| ENERGY TARIFF | Unknown |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | NO DATA! |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | 2110 |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 12 |
| NUMBER HEATED ROOMS | 12 |
| LOW ENERGY LIGHTING | 0 |
| NUMBER OPEN FIREPLACES | 2 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Very Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| MAIN FUEL | mains gas - this is for backwards compatibility only and should not be used |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | NO DATA! |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 3.3 |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ADDRESS | Granville House, Granville Road |
| LOCAL AUTHORITY LABEL | Elmbridge |
| CONSTITUENCY LABEL | Runnymede and Weybridge |
| POSTTOWN | WEYBRIDGE |
| CONSTRUCTION AGE BAND | England and Wales: 2007 onwards |
| LODGEMENT DATETIME | 2009-03-31 21:37:11 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | — |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 100061344310 |
| UPRN SOURCE | Address Matched |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |