Energy Performance Certificate

20, Lawson Road, LL29 8HB

EPC Report

Energy rating

Current: 35 F | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 28 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 68 Potential: 68
Field Value
LMK KEY 1113405669262016102618584611458506
ADDRESS1 20, Lawson Road
ADDRESS2
ADDRESS3
POSTCODE LL29 8HB
BUILDING REFERENCE NUMBER 0176631278
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-10-25
LOCAL AUTHORITY W06000003
CONSTITUENCY W07000059
COUNTY
LODGEMENT DATE 2016-10-26
TRANSACTION TYPE none of the above
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 419
ENERGY CONSUMPTION POTENTIAL 155
CO2 EMISSIONS CURRENT 15.0
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 166
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 2906
HEATING COST POTENTIAL 1244
HOT WATER COST CURRENT 117
HOT WATER COST POTENTIAL 117
TOTAL FLOOR AREA 202.0
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL NODATA!
FLAT TOP STOREY
FLAT STOREY COUNT
MAIN HEATING CONTROLS 2107
MULTI GLAZE PROPORTION 5
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF NO DATA!
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR NO DATA!
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.75
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20, Lawson Road
LOCAL AUTHORITY LABEL Conwy
CONSTITUENCY LABEL Clwyd West
POSTTOWN COLWYN BAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-10-26 18:58:46
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT
LOW ENERGY FIXED LIGHT COUNT
UPRN 100100419936
UPRN SOURCE Address Matched
REPORT TYPE 100
Address display
Nation ew