Energy Performance Certificate
MEREGARTH, OLD HALL ROAD, TROUTBECK BRIDGE, LA23 1JA
Energy rating
Current: 79 C | Potential: 83 B
Environmental impact (CO₂)
Current: 72
| Potential: 76
| Field | Value |
|---|---|
| LMK KEY | 0efec2286b1e616543fc78de1913cf30044c4571bbd0a642f964e87cb18b586d |
| ADDRESS1 | MEREGARTH |
| ADDRESS2 | OLD HALL ROAD |
| ADDRESS3 | TROUTBECK BRIDGE |
| POSTCODE | LA23 1JA |
| BUILDING REFERENCE NUMBER | 10001281893 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2021-06-21 |
| LOCAL AUTHORITY | E07000031 |
| CONSTITUENCY | E14001037 |
| COUNTY | Cumbria |
| LODGEMENT DATE | 2021-06-24 |
| TRANSACTION TYPE | marketed sale |
| ENVIRONMENT IMPACT CURRENT | 72 |
| ENVIRONMENT IMPACT POTENTIAL | 76 |
| ENERGY CONSUMPTION CURRENT | 135 |
| ENERGY CONSUMPTION POTENTIAL | 116 |
| CO2 EMISSIONS CURRENT | 24.9 |
| CO2 EMISS CURR PER FLOOR AREA | 24 |
| CO2 EMISSIONS POTENTIAL | 21.6 |
| LIGHTING COST CURRENT | 553 |
| LIGHTING COST POTENTIAL | 276 |
| HEATING COST CURRENT | 4271 |
| HEATING COST POTENTIAL | 4306 |
| HOT WATER COST CURRENT | 117 |
| HOT WATER COST POTENTIAL | 117 |
| TOTAL FLOOR AREA | 1048.0 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| FLAT STOREY COUNT | — |
| MAIN HEATING CONTROLS | — |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 14 |
| NUMBER HEATED ROOMS | 14 |
| LOW ENERGY LIGHTING | 0 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas, Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and at least two room thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 1.0 |
| PHOTO SUPPLY | 0.0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | MEREGARTH, OLD HALL ROAD, TROUTBECK BRIDGE |
| LOCAL AUTHORITY LABEL | South Lakeland |
| CONSTITUENCY LABEL | Westmorland and Lonsdale |
| POSTTOWN | WINDERMERE |
| CONSTRUCTION AGE BAND | England and Wales: 2003-2006 |
| LODGEMENT DATETIME | 2021-06-24 15:30:51 |
| TENURE | Owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 100 |
| LOW ENERGY FIXED LIGHT COUNT | — |
| UPRN | 100110701334 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 100 |
| Address display | — |
| Nation | ew |